Aircon With EFC

Description

Capacity: 1TR/1.25TR/2TR/3TR with EFC

Specifications

PARTICULARS

UNITS

INFOKOOL SPECIFICATION

 

 

IK-PAC07-A-EFC

IK-PAC10-A-EFC

GENERAL INFORMATION

 

 

 

Cooling Capacity

TR

2

3

Units net sensible cooling capacity

TR

1.8

2.7

Type

 

External wall mounted , Displacement type PAC with Emergency Free Cooling

External wall mounted , Displacement type PAC with Emergency Free Cooling

Air discharge

 

Bottom Horizontal

Bottom Horizontal

Indoor design condition

DBT/RH

27 deg c +/- 1 deg C / 50% +/-5% RH

27 deg c +/- 1 deg C / 50% +/-5% RH

Type of duty operation

HRS

24 Hrs

24 Hrs

 

 

 

 

COMPRESSOR

 

 

 

Type

 

Scroll /Rotary

Scroll /Rotary

No of Compressor / unit

Nos

1

1

Refrigerant

 

R-22

R-22

Compressor motor phase

 

1 Ph.

3 Ph

No of Condenser / unit

Nos

1

1

No of fan / condenser

Nos.

1

1

Total nos. of fan per unit

Nos.

1

1

External static pressure

mm wg

Free outlet

Free outlet

Volts

V+/-%

230 +/- 15%

230 +/- 15%

Frequency

HZ+/-%

50+/-5%

50+/-5%

Phase

 

1 PHASE

1 PHASE

Model/Type

 

EC Centrifugal fan

EC Centrifugal fan

Make

 

EBM

EBM

Discharge type

 

Yes

Yes

No of Evaporator/unit

Nos

1

1

No. of fan /evaporate

Nos

1

1

Total nos. of fan per unit

Nos

1

1

Air flow per unit

CFM

1190

1750

Blower ESP

mm of WG

Free flow

Free flow

Power

Kw

0.21

0.31

Volts

V+/-%

48 V DC

48 V DC

UNIT CASING

 

 

 

Casing material

 

G.I Sheet // Powder Coated

G.I Sheet // Powder Coated

Thickness

MM

0.9 mm -1.6 mm Thick

0.9 mm -1.6 mm Thick

Single/Double skin insulation thickness

 

Evaporator side double skin; 15 mm Thick

Evaporator side double skin; 15 mm Thick

 

 

 

 

DIMENSIONAL DETAILS

 

 

 

Width

mm

930

930

Depth

mm

700

700

Height

mm

2200

2200

Weight

kgs

210

280

Front clearance

M

1

1

Side clearance

M

1

1

Top clearance

M

2

2

Bottom Clearance

M

0.3 from inside shelter

0.3 from shelter

Features

  • Industrial DC operated package unit running on 48 V DC.
  • High sensible cooling with high static backward curve fans.
  • Unit has HT, LT, LP, HP, OV, UV etc Alarms with PFC contact.
  • Soft Start with intelligent controller.
  • Aircon with EFC in one package with compact modular design.
  • Mesh Filter provided for dust protection with EFC & FC operation.
  • Rain louver is provided for rain protection during operation in FC & EFC mode.
  • Closed loop design.
  • Log of EFC running hours and comp running hours.
  • Contactor is provided for reducing the power consumption during power cut and switch over to EFC mode with only Blower fan running with minimal power consumption.
  • Alarms can be extended to customer for monitoring purpose.